G3X Instrument Panel Top Panel Installation
100350-01
Use the following task to install the IP Top. This task is applicable to the Garmin G3X configuration only.
Applicable Aircraft Serial Numbers
00139+ (Applicable to the G3X Configuration Only)
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
ITL001563 (AIR VALVE INSTALLATION TOOL)
Parts Required
5Y03651 (CLAMP, HOSE, HAND TIGHTENED, 2.125)
2x 8C50MTT3 (SCREW, TRUSS, 6 LOB, 8-32 X .50, SS316)
2x 91770A148 (SCREW, MACH, TRUSS HEAD, 6-32 X.5)
2x NAS1149CN632R (WASHER, FLAT, CRES, #6, .032 THK, PSVT FNSH)
ME001107-NSG3X-A (PAINTED, PANEL, IP TOP, RH)
ME001106-NSG3X+A (PAINTED, PANEL, IP TOP, LH)
AV467408-1 (AIR VALVE, DISC TYPE, 1.50)
Aircraft System and Number
10—Instruments (and Avionics)
Safety Equipment
As Needed
Consumables
ICA012078 (LUBRICANT, GENERAL PURPOSE)
Isopropyl Alcohol
Task Instructions
1. Place the LH side IP top into position over the LH crossbeam.
Figure 70. LH Side IP Top
2. Connect vent hose. With the LH side IP Top still loose, connect the LH hose to the forward side of the IP top and secure with the clamp.
Figure 71. LH Side IP Top
Note: 
Hand tighten the clamp so as the ensure retention of hose but not crush IP Top.
3. Install the RH side IP Top into position over the RH crossbeam.
4. With the RH side IP top still loose, connect the previously installed vent hose to the forward side of the RH side IP top and secure with the clamp. Cut the hose to length as needed.
Figure 72. RH Side IP Top
Note: 
Hand tighten the clamp so as the ensure retention of hose but not crush IP Top.
Note: 
Center spine is not shown for clarity but should already be installed.
5. Using isopropyl alcohol, clean surfaces where lubricant will be applied.
6. Apply lubricant liberally to the threads and shanks of screws.
7. Secure RH IP top into place with hardware. Secure LH IP top into place with hardware. Insert the IP top flange into the Garmin G3X Bezel clip.
Figure 73. LH IP Top
8. Install the air valve into RH IP top using installation tool ITL001563. Hand tighten air valve until snug.
Verification Method
Verify air valve is not loose and does not loosen easily.