Calibrate AOA Pressure Transducer
100280-00
The following section contains the information necessary to perform the calibration of the AOA pressure transducer.
Applicable Aircraft Serial Numbers
All
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Safety Equipment
As Needed
Consumables
None
Task Instructions
1. Turn on the master switch (or confirm on).
2. Locate the calibration push button switch on the bottom side of the MSC computer.
Note: 
The MSC computer is located behind the right hand crossbeam and can be reached through the passenger footwell.
3. Press button and hold for 5 seconds.
Note: 
During this time, an LED next to the switch will flash at a 2 Hz rate and flashes a GREEN indicator.
4. The light goes solid GREEN at the end of the calibration mode. If there are any errors the light is left in a solid RED illuminated state.
5. Turn off the master switch.
Verification Method
Increased accuracy and the ability to adjust for sensor aging and varying environmental conditions to obtain the most accurate result possible.
Inspect the indicator LED to ensure that it is solid GREEN color.