Install Low Fuel Level Sensor (00110+)
100354-01
Use this procedure to install the Low Fuel Level Sensor.
Applicable Aircraft Serial Numbers
00110+
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
ICA014185 (SENSOR, ULTRASONIC, DRY, 1/2-20, 12VDC)
TY24MX (CABLE-TIE, NYLON 6-6, 30LB, 5/50, TY-RAP)
Aircraft System and Number
10—Instrument (and Avionics)
Safety Equipment
As Needed
Consumables
LOCTITE 222 (THREADLOCKER, PRIMERLESS, OIL TOL, REMOVABLE LOW STR, BLUE)
Task Instructions
1. Apply LOW STR THREADLOCKER to the new DRY ULTRASONIC SENSOR and install into the Fuel Tank. Torque to 45-55 in-lbs.
2. Connect the Dry Ultrasonic Sensor connector to D9038P on the Main Fuselage Wire Harness.
3. Secure connector and cable with 3X CABLE-TIEs.
4. Install RH Seat Back. (Install Seat Back)
5. Install the Baggage Floor. (Baggage Floor Installation)
Verification Method
The task is complete when the low fuel level sensor has been installed without leaks.